How long will a portable power station run a space heater?
Calculated runtime for Vornado space heaters on high and low on six power stations, which stations can't run one at all, and why a power station is a poor way to heat a room.
Last updated
- 8 power stations
- 5 devices
As an Amazon Associate I earn from qualifying purchases. How we make money
Short answer: not for long, and we wouldn’t plan on it. A space heater on high is about the hungriest thing you can plug into a power station. A Vornado AVH2 on high empties an EcoFlow DELTA 2 in about 0.6 hours, and on low you get 1.2 hours. Even the EcoFlow DELTA Pro, the biggest station in our data, lasts 4.0 hours on low. That’s an evening at best. The small stations can’t run these heaters at all, not even on low.
Which stations can run one
All five Vornado heaters on this page have the same two ratings in their owner’s guides, one for high and one for low. So a single check covers all of them.
4 of 6 power stations below can run the Vornado AVH2 in every listed mode.
| Power station | Mode | Runs it? | Why |
|---|---|---|---|
| EcoFlow RIVER 3 Plus | High heat setting (rated) | No | AC: Needs 1,500 W, inverter limit is 600 W |
| EcoFlow RIVER 3 Plus | Low heat setting (rated) | No | AC: Needs 750 W, inverter limit is 600 W |
| Bluetti EB3A | High heat setting (rated) | No | AC: Needs 1,500 W, inverter limit is 600 W |
| Bluetti EB3A | Low heat setting (rated) | No | AC: Needs 750 W, inverter limit is 600 W |
| EcoFlow DELTA 2 | High heat setting (rated) | Yes (surge unverified) | AC: 1,500 W is within the 1,800 W inverter limit; AC: Startup surge not specified |
| EcoFlow DELTA 2 | Low heat setting (rated) | Yes (surge unverified) | AC: 750 W is within the 1,800 W inverter limit; AC: Startup surge not specified |
| Jackery Explorer 1000 v2 | High heat setting (rated) | Yes (surge unverified) | AC: 1,500 W is within the 1,500 W inverter limit; AC: Startup surge not specified |
| Jackery Explorer 1000 v2 | Low heat setting (rated) | Yes (surge unverified) | AC: 750 W is within the 1,500 W inverter limit; AC: Startup surge not specified |
| Bluetti Elite 200 V2 | High heat setting (rated) | Yes (surge unverified) | AC: 1,500 W is within the 2,600 W inverter limit; AC: Startup surge not specified |
| Bluetti Elite 200 V2 | Low heat setting (rated) | Yes (surge unverified) | AC: 750 W is within the 2,600 W inverter limit; AC: Startup surge not specified |
| EcoFlow DELTA Pro | High heat setting (rated) | Yes (surge unverified) | AC: 1,500 W is within the 3,600 W inverter limit; AC: Startup surge not specified |
| EcoFlow DELTA Pro | Low heat setting (rated) | Yes (surge unverified) | AC: 750 W is within the 3,600 W inverter limit; AC: Startup surge not specified |
Last updated 2026-11-13. How we check compatibility
Look closely at the Jackery Explorer 1000 v2 rows. It passes on high, but only because its inverter limit is exactly the heater’s high rating. That leaves no headroom at all, and we’d use low on that station.
Vornado doesn’t publish a startup figure, so the passing rows say “surge unverified”. What empties the battery is the steady draw in the tables.
Where these numbers come from
The heat settings in the owner’s guides are rated values. A heater’s thermostat switches the element off once the room is warm and back on when it cools, so over a few hours the average draw can be lower than the rating. How much lower depends on the room. In a cold, drafty space the heater will be on most of the time, and you’ll get close to the table. In a small, well-insulated room you’ll do better, but we can’t tell you by how much.
Everything here is calculated, not measured. We take the station’s rated capacity, apply an AC efficiency factor (our assumption, printed under the table) and divide by the rated draw. We haven’t run any of these heaters on these stations.
Runtime by station
One table covers all five heaters: the Vornado AVH2, Vornado AVH4, Vornado VMH300, Vornado VMH500 and Vornado VTH. Their published ratings match, so their rows would be identical. We left out the small stations, since they failed the check above. The runtime calculator has the rest of the stations in our data.
The Vornado AVH2 runs on AC power for 0.6 to 4.0 hours, depending on the power station and mode.
| Power station | Rated capacity (Wh) | Mode | Power path | Runtime (hours) |
|---|---|---|---|---|
| EcoFlow DELTA 2 | 1,024rated spec | High heat setting (rated) | AC | 0.6calculatedsurge unverified: Startup surge not specified |
| EcoFlow DELTA 2 | 1,024rated spec | Low heat setting (rated) | AC | 1.2calculatedsurge unverified: Startup surge not specified |
| Jackery Explorer 1000 v2 | 1,070rated spec | High heat setting (rated) | AC | 0.6calculatedsurge unverified: Startup surge not specified |
| Jackery Explorer 1000 v2 | 1,070rated spec | Low heat setting (rated) | AC | 1.2calculatedsurge unverified: Startup surge not specified |
| Bluetti Elite 200 V2 | 2,073.6rated spec | High heat setting (rated) | AC | 1.2calculatedsurge unverified: Startup surge not specified |
| Bluetti Elite 200 V2 | 2,073.6rated spec | Low heat setting (rated) | AC | 2.5calculatedsurge unverified: Startup surge not specified |
| Bluetti AC200PL | 2,304rated spec | High heat setting (rated) | AC | 1.3calculatedsurge unverified: Startup surge not specified |
| Bluetti AC200PL | 2,304rated spec | Low heat setting (rated) | AC | 2.5calculatedsurge unverified: Startup surge not specified |
| Jackery Explorer 2000 v2 | 2,042rated spec | High heat setting (rated) | AC | 1.2calculatedsurge unverified: Startup surge not specified |
| Jackery Explorer 2000 v2 | 2,042rated spec | Low heat setting (rated) | AC | 2.5calculatedsurge unverified: Startup surge not specified |
| EcoFlow DELTA Pro | 3,600rated spec | High heat setting (rated) | AC | 2.0calculatedsurge unverified: Startup surge not specified |
| EcoFlow DELTA Pro | 3,600rated spec | Low heat setting (rated) | AC | 4.0calculatedsurge unverified: Startup surge not specified |
Last updated 2026-11-13. Bars are scaled to the longest runtime in this table. Assumptions: AC efficiency 85% assumed. How we calculate runtime
So what should you do?
If you need heat through a power cut, a power station only gives you a short burst of it. Use low rather than high, heat one small room with the door shut, and switch the heater off when you’re warm enough. That roughly doubles your hours over high, and it’s still not a night.
For staying warm overnight in a tent or a van, heat yourself instead of the air: a sleeping bag rated for the temperature, a warm layer, a hat. Don’t swap in a mains electric blanket either. The one brand in our data says not to use its blankets with inverters, which is what a power station’s AC outlet is. We cover that on our electric blanket page.